Umbrella online temperature sensor. ZONT - H Thermostats for remote control of the boiler. Alert when room temperature changes

Buy Zont H-1 GSM-Climate- means getting ownership of a compact thermostat with its own SIM card from any operator, which allows you to control the indoor climate from any phone (satellite, mobile or fixed line), tablet or PC. Manufactured by Micro Line specifically to order Russian manufacturer heating boilers Evan.

Zont H1 GSM-Climate will ensure economical consumption of fuel spent by the boiler for heating, will allow you to remotely set the temperature in the house and monitor the proper operation of the heating boiler, as well as remotely control its operation!
Agree that manual control heating devices is quite troublesome, and from a distance it is almost impossible. With the Zont H 1 unit, remote control of the heating system is not only possible, but also extremely simple and convenient! No matter how far from home you are, all you need to do is call or send a command with mobile phone or via the Internet to change the heating boiler mode and ensure a comfortable temperature in the house. Convenient, isn't it?

New opportunities!

Additional functions of the device allow you not only to save heating costs and control the operation of the heating boiler, but also to monitor the safety of the facility! The user can connect additional sensors, for example, motion, disconnection, water leaks, gas leaks, fire and smoke sensors, etc. Information is transmitted through channels mobile communications and the Internet.

Features of Zont H-1 GSM-Climate

Supports various preset temperature modes:
Economy - economical fixed temperature.
Comfort - a comfortable fixed temperature (usually a few degrees higher than the economical temperature).
Schedule - maintaining the set temperature according to a schedule.
Off - anti-freeze mode
Alarm – thermostat operating mode when the temperature sensor is faulty.

The module will call only the owner’s phone or trusted numbers determined by him, warning him about all changes or emergency situations. Accordingly, Zont GSM-Climate can receive commands only from the owner or from “its” phones. Unauthorized access is absolutely excluded - even if someone dialed the number by mistake, the device will ask for a password that only the owner and, for example, other family members or trusted persons know. In addition to SMS control, it is possible to control via the voice menu.
Actually GSM module Climate Umbrella H1 acts as your personal assistant- called him, gave the command, for example, to heat it hotter in advance, and the whole family would eventually come to a warm and cozy home. Or vice versa: if you forgot to turn down the power in the morning when leaving for work - no problem, you can do it right from work, via the Internet.

Unlike competitors, it does not have a control panel and all monitoring and control operations are performed using either personal computer, or mobile devices: a smartphone or tablet, which allows the owner to control the situation wherever he is, while significantly reducing the cost of the equipment.
Zont-H1 unit works even when lost cellular communications, executing, for example, a predetermined weekly schedule.
It is possible to use control commands in the form of SMS text and even using voice menu.
Used simple, functional and convenient GUI via web browser or mobile app. All data is stored on the server and at any time you can view convenient and visual system operation graphs, information messages, or make the necessary settings.
Most boilers have terminals closed with a jumper (corresponding to the boiler being on) for connecting a room thermostat. It is to these terminals that the Zont-H modules are connected: this jumper is removed and the Zont H relay contacts are connected in its place.

New!

Weather-dependent automation - energy-efficient heating control taking into account changes in outside temperature (the function is available for modules with firmware version 122:74 and higher)

How does the GSM-Climate thermostat control the boiler?

The thermostat measures the room temperature and turns the output relay on or off, controlling the operation of the boiler in heating mode so that the room temperature corresponds to the set value.
It controls the temperature in the house and outside, the supply voltage, the technical condition of the boiler and signals in the event of an accident or power failure. If the values ​​deviate from the specified ones, it informs the owner in any pre-selected way: call, SMS message or notification via the Internet.

To use the Internet service, you do not need to install additional software; work is carried out using any modern WEB browser. Access to the Internet service is provided through a personal page on the zont-online.ru server
From your personal account on the Internet service zont-online.ru, you need to set the desired indoor temperature values, as well as threshold levels for generating alarm messages when the temperature deviates to a critical (emergency) value.
The unit analyzes changes in indoor temperature using its own remote temperature sensor. Depending on the measurements taken, it turns on or off the output relay, which controls the operation of the boiler in heating mode so that the indoor temperature corresponds to the value of the set operating mode.
If a boiler malfunction occurs, the system will immediately notify the owner of this event, which will help avoid troubles.

Functionality of the GSM thermostat Zont H-1 GSM-Climate

Remote control of the boiler operation can be carried out:
- SMS commands;
- when dialing a SIM card number using the voice menu;
- via the Internet (WEB interface and mobile applications for Android and iOS devices).

Convenient and simple WEB interface with the following capabilities:
- displaying the current state of the boiler and room temperature;
- boiler operation control;
- temperature monitoring (inside, outside the room, coolant) for any selected period of time;
- programming the boiler operation according to a schedule;
- notifications about the activation of additional sensors.

Various event alerts:
- when the measured temperature deviates from the specified threshold values;
- about a boiler failure (provided the thermostat is connected to the emergency output of the boiler);
- about a malfunction of the temperature sensor and the thermostat going into emergency mode;
- about the loss or restoration of power supply, in which case it is necessary to have a backup battery;

The event log
- a diary of measured temperatures for any period without a statute of limitations;
- date and time of detection of the boiler failure;
- date and time of changing the operating mode of the boiler and thermostat;
- list of executed control commands via voice menu, transmitted by SMS, software updates;
- date and time of loss or restoration of power supply.

Signaling about the status of additional sensors connected to the “Alarm” input of the thermostat;
Memorizing events:
- temperature sensor readings;
- date and time of the boiler accident;
- changes in operating modes;
- voice menu commands
- SMS commands;
- updates software(BY);
- power on/off.
Update the current version of the unit’s firmware without turning it off and removing it from the user’s personal account.

Connection diagrams for the Zont H-1 GSM-Climate thermostat

Scope of delivery Zont H-1 GSM-Climate

Thermostat
Mounting base
Digital temperature sensor
Terminal blocks (2 pcs.)
Network adapter 220/12 V.
External GSM antenna
Passport
Backup battery (optional)

Technical characteristics of the Zont H-1 GSM-Climate thermostat

Article: 112005 (Evan), ML12074 (Micro Line)
Manufacturer: Micro Line (ordered by Evan)
Supply voltage, volts: 10 - 28
Maximum current consumption, mA: 150
One analog input
One dry contact output (make/break)
Maximum voltage of switched relay contacts: AC. 120 V DC 24 V
Maximum current through relay contacts, mA: 1000
Adjustable hysteresis, °C: +/-0.1 - 2
Voice interface: yes
WEB interface: yes
1-Wire interface: yes
Operating temperature range, °C: from -30 to +55
GSM modem frequency ranges, MHz: 800, 900, 1800, 1900
GPRS data channel: yes
External GSM antenna: yes
Internal non-volatile memory: yes
Time to reach operating mode, sec: no more than 50
Overall dimensions, mm: 77 x 86 x 33
Weight, grams: 200
High-strength plastic housing
Additional compatible equipment Zont: ML-489, ML-703, Zont Home, OpenTherm interface, Astra-9, Astra 512, Astra C, IO 102-16/2, Astra 361, ML-711, ML-712


Smart thermostat ZONT (ZONT models H-1, H-1V and H-2) is designed to meet the needs of vacation home users. The peculiarity of the situation is when there is no one in the house, but you need to be sure that the heating system is working. Moreover, the inertia of the heating system requires changing the boiler mode long before the owners arrive. All this can be solved with the help of our devices and Internet service. ZONT.

Features and principle of operation

Thermostat Feature ZONT-H is that it is focused on the use of the Internet. Now the main trend in this area is cloud service And that's exactly how the thermostat works. Unlike most competitors, it does not have a home control panel. All monitoring and control operations are performed using either a personal computer or mobile devices - a smartphone or tablet. This significantly reduces the cost of equipment, while at the same time allowing the user to control the situation wherever he is.

Thermostat ZONT - H It also works when the connection is lost, executing a predetermined program, for example, a weekly schedule. Additionally, it is possible to use control commands in the form of SMS text and even using the voice menu.

The user has the opportunity to use a very functional and powerful graphical interface through a web browser or mobile application. Convenient and visual graphics, information messages and settings are available. Data from the product is stored on the server and the user can view the entire history of events and parameters. The user interface is carefully designed and highly appreciated by numerous customers.

To meet the needs of different user groups, various models are produced, differing in the type of connection - GSM or WiFi. Structurally, some models are made in a small-sized case of their own design, others - in a standard case on a DIN rail for installation in an electrical cabinet.

The thermostat has 2 inputs for connecting various additional devices.
On Input 1 can be connected: or ; or with "Boiler failure" signal; or External room thermostat.

On Input 2 can be connected: or Security sensors and detectors; or with "Boiler failure" signal; or External room thermostat; or Interface OpenTherm And Radio module ML-489.

- Security sensors and detectors , connected to one input must be of the same type in connection method. Number of sensors in the loop - ICD, MKD, etc. no more than 10 pieces; water leak and gas leak detectors no more than 5 pcs. The maximum distance of the latter in the train is 100 m.

- WITH “Boiler failure” signal. To monitor the technical condition of the boiler and generate an alert about its emergency condition, the thermostat can be connected to the emergency output of the boiler.

- Room thermostat . By connecting an external room thermostat, it becomes possible to control the boiler either through ZONT-H 1 and through an external room thermostat, the choice of how control is carried out is made remotely via the Internet service or SMS command "Manual mode".

When operating from an external thermostat, remote monitoring of the room temperature and all alert modes (accidents, power loss/restoration, alarm events, etc.) will be maintained.

- Radio module ML-489. Thermostat interface module ZONT with radio devices It provides reception and relaying of information from radio devices to the ZONT server

For boilers that have a computerized OpenTherm interface There is an adapter that allows you to expand control and monitoring functions and ensure fuel savings through advanced system operation algorithms.

How to choose and operate thermostats correctly ZONT?

Models ZONT H-1 and ZONT H-1V have a GSM communication channel and are designed for very little Internet traffic. Therefore, the price of the subscription fee to the mobile operator is minimal

The ZONT H-2 model has a WiFi communication channel and is used where a wireless local network already exists.

1. Internet traffic is about 60 MB per month*

*indicated taking into account rounding to 100kb per hour

It is important to take into account that the actual consumption of Internet traffic highly depends on the nature of the device’s use and the quality of the connection. Accordingly, the worse the connection conditions, the more often the device reconnects to the server, and the more traffic is consumed.

To subscription fee was easily predictable, we recommend choosing tariffs with unlimited traffic.

Many operators offer tariffs in which the Internet speed drops when a certain limit is reached. Such tariffs are also good because ZONT devices do not have special requirements for connection speed.

If you choose a tariff with per-megabyte payment for traffic, then pay attention to the amount of traffic rounding. At great importance rounding (for example, more than 100 KB), the operator may count many times more traffic than the device actually consumes. How smaller size rounding is better.

2. Calls and SMS

ZONT devices use voice calls and SMS messages only for alarm notification, therefore, choose a tariff based on the expected number of alerts.

Attention! There are tariffs that are incompatible with work ZONTA

  • From November 2015 on MTS Smart tariffsInternet operation is blocked in 3G modems . Along with modems, the operator also blocks our devices.
  • Option "Tablet XS" from MegaFonDesigned for use on tablets only , and in ZONT devices either does not work at all or leads to constant loss of communication.

Important!

Reflashing is an extremely desirable step when you first turn it on. The fact is that in production the product receives the current firmware, and the user prefers to have the latest one. So we recommend that you reflash the thermostat before using it.

Flashing should be carried out under user control. Since the communication channel is usually unreliable, you need to make sure that the flashing procedure is successful and the product is connected again.

Video about ZONT H1V:

YouTube Video

How to set up a power outage alert

Settings - thermostat settings - input No. 2 - "panic button"
- - emergency input polarity - "ground fault"
- -alerts-alarming events-"your phone"-"envelope"
-save

Instead of "input 2" you can also use "input 1". For ZONT-H1V it’s basically the same, just different contacts.

The difference between ZONT H-1V and ZONT H-1 is as follows:

  • the relay in H-1V holds 220V. The relay in H-1 is rated for 120V;
  • ZONT H-1V has a 220V->5V adapter for converting a high-voltage boiler alarm signal (available in Vaillant) into a low-voltage one for the ZONT input;
  • relays have opposite logic - the information is outdated, it corresponds to products produced before xxx 2015 (see the section “connection to the boiler”):
    • ZONT H-1 - the boiler heats up when the relay is energized. If the power is lost, the relay turns off. The internal battery does not power the relay, so it does not help turn the relay on. Therefore, when planning the system layout, you need to take this into account, for example, power the Umbrella and the boiler from the same UPS;
    • ZONT H-1V - the boiler heats up when the relay is de-energized. Therefore, if the power goes out, the relay turns off, but the boiler turns on with the relay contacts. The umbrella can be hung without a UPS, it will know about a power failure and send an SMS about it;
  • The battery in the H-1V is built-in, while in the H-1 it is not even included in the basic kit. It can be purchased in addition;
  • and most importantly, the firmware of both options is the same. Schemes, almost the same. Different cases;

Connection to the WAMOS QX boiler (EVAN)

(This scheme is not suitable for other Evan boilers)

The umbrella, wanting to turn on the boiler, closes 1-3, opens 1-2.

The boiler has an IN input. Although it is called the air temperature sensor input, we use it as an input for connecting a thermostat. You can use another, alternative input - a heated floor sensor. They are essentially the same.

The ZONT H1 relay is connected as follows. The central contact of the relay (1) is connected to the IN input. The normally closed relay contact (2) is connected to the “-” input. The normally open relay contact (3) is connected to the “+” input.

To make it clear, the “+” and “-” contacts of the boiler are connected to the 5V power circuit. As a result, the ZONT H1 relay switches them to the IN input.

Test of the first start-up of the boiler, using the example of EVAN WARMOS QX

  1. Set the set temperature lower than in the room. Make sure that the boiler inlet is ZERO. The boiler should not heat;
  2. Set the set temperature higher than in the room. Make sure that the boiler input is +5V. Actually, the boiler must heat the water, and without a multimeter it will be clear that the pipe is getting hotter and hotter.

Thermal sensor

All sensors are connected in parallel. The web interface has a procedure for assigning a “own name” to each sensor.

Please note that there are many modifications of these sensors on the market and they differ in discreteness. The product comes with a DS18S20 sensor with a resolution of 0.1 degrees. Sometimes users buy sensors externally. Therefore, we provide additional information on different types sensors:

  • DS1820 is an old, discontinued model. It differs in its elongated body from all new models. It has a capacity of 9 bits, which leads to a discreteness of 0.5 degrees;
  • DS18 S 20 - Has a capacity of 12 bits, recommended for use. Note that manufacturers label the microcircuit as DS1820, so it can only be distinguished by the size of the case, it is shorter;
  • DS18 B 20 - Has a different operating protocol. The ZONT H1 program supports 12 bits for it, that is, a discreteness of 0.1 degrees;

If you already have a room thermostat and want to include ZONT - H in the gap between the boiler and the room thermostat?

Yes, now it is possible. To do this, you need to connect the room thermostat to one of the thermostat inputsZONT.

This connection allows you to control the boiler remotely (via ZONT ) and manually, according to commands from this room thermostat. The choice of control method is carried out via the Internet service or SMS command "Manual mode".

When operating from a room thermostat, remote monitoring of temperatures and all alert modes (accidents, power loss/restoration, alarm events, etc.) are maintained.

Many people are interested in how the discrete inputs of ZONT H are made?

  • Input 2 - may have options:
  • Input 1 - may have options:

Relay contacts

Relay diagram:


It can be seen that when the power is turned off, contacts 1 and 2 are closed. This must be taken into account, keeping in mind the situation with power failure. The boiler usually turns off when the control contacts open and turns on when they close. But there are also opposite options!! Then an external relay is required, which inverts the operating logic. This relay is switched on by the ZONT H contacts.

Often ZONT H is turned on together with the boiler via an Uninterruptible Power Supply (UPS).

First steps to turn on the GSM thermostat ZONT H

  1. Preparation and setup
    1. Buy a SIM card (standard size, no micro- or nano-SIM) and top up its balance. Minimum requirement - 5-10 MB and 10 SMS (while you play with the settings, you’ll just spend it);
    2. Before using it in the product, it is better if you already have it configured Personal Area on the telecom operator's website. It will help you see the dynamics of money and traffic consumption and solve emerging problems.
    3. Have a suitable place where you record and save accounts and passwords. You will need to do this for your personal account. SIM cards, for the ZONT web interface, for the access password from the phone. It's amazing how often we forget passwords :-)
    4. Before connecting the device to the boiler, set it up “on the table”:
      1. Register yourself on the sitehttps://zont-online.ru/
      2. Register the device on the same website - there is a “add device” sign there.
      3. Install the SIM card (open the receiving clip, fold it up, insert the SIM card into the slots with the cut corner up, soldering the SIM card to the contacts)
      4. Connect the included antenna (there is no internal antenna, so this is required). Please note that if the room is in the basement or in an area of ​​poor reception, then the antenna should be placed as high as possible
      5. Connect the temperature sensor and power supply (AC adapter).
      6. < > Dial an SMS in your phone about resetting to factory settings. There are a lot of letters, and the time for sending will be limited, so we advise you to type the text in advance. Don't send SMS yet.
      7. < This item is optional. Needed if there is no web interface> Enter the SMS text into your phone about the registration of your phone. There are a lot of letters, and the time for sending will be limited, so we advise you to type the text in advance. WITHwrite serial number small letters and what comes after serial number must be done space and be sure to write the word " Telephone ", and write the number without any hyphens between the numbers. Do not send an SMS yet.
      8. Connect the connectors and apply power
      9. Wait for one of two options for a green signal on the device:
        1. so that it lights up constantly and sometimes goes out for a split second several times in a row (indicates that there is a network and the signal level is normal). This is an option when there is both a GSM connection and a connection to the server;
        2. so that it flashes in a series of flashes, at least two flashes, with a pause between flashes.This is an option when the GSM connection is established, but there is no connection to the server. In this case, SMS can be used.
      10. EIf the green indicator flashes only once for a short time, it means there is no GSM connection and there is no point in sending SMS.
      11. < This item is optional. Required if the SIM card is NOT a MEGAFON or the device was released before September 2015> Send an SMS with the APN access point setting. How to do this is written in the instructions.
      12. Log in to the web interface and wait for the device to become connected. After this, you can add a phone number for voice and SMS notifications in the web interface settings. If this is done, then there is no need to send an SMS with the same number. That is, paragraph 14 is not required.
      13. <This item is optional. Most likely, it will be required if the procedure is repeated. If for some reason the first pass didn’t work out>Send SMS about factory reset.After resetting to factory settings, you will need to remove the device from the list and add it again.
      14. <This item is optional. Needed if there is no web interface>Send SMS about the registration of your phone. Wait for the response message “phone number has been established.”
  2. Before connecting to the boiler
    1. Try to find out the type of connection (normally closed or normally open), it depends on which contacts on the block the wire from the boiler is connected to. To do this, you need to study the documentation for the boiler. You can simulate it by connecting a jumper and make sure that the boiler reacts correctly
    2. Install the device and sensors permanently
  3. Connection
    1. Connect the wires from the boiler
    2. Change modes and monitor the boiler’s reaction
    3. As soon as the boiler begins to respond adequately to the control input, you can begin setting up modes

Battery backup and UPS

Battery backup power in the ZONT thermostat is intended only to inform the server and owner via SMS about the loss of the main 220V power supply. Usually the boiler cannot operate without main power, so there is no point in controlling the boiler in this situation.

Sometimes the user installs a UPS - an uninterruptible power supply. It connects to the boiler and it is logical to power ZONT from it. But a problem arises: ZONT does not recognize the loss of the main 220V power supply. In this case, you can select “Boiler emergency” for notification. You can buy any cheap power supply or charger with an output voltage of 5V and connect it to this input. The circuit, unfortunately, requires a couple more parts - a resistor (any) and a diode (any):


Configure Input 2 in the web interface to the "ground fault" mode.

Some UPSs have a main power failure output. Then you just need to connect it to Input 2 and select one of the “Input Polarity” options - “open” or “short”.

It is important to add that SMS and web notifications will be sent not only when an accident occurs, but also when it disappears.

Color of the temperature sensor wires included in the delivery kit

The two-strand wire used is misleading to some. It’s worth taking a closer look; let’s call the one that’s “more red” “red.” The one that is “blacker” will be called “black”. If it's completely unclear, don't be afraid. Turn it on at random and if the sensor works, you will see the readings in the web interface. You can heat one in order to distinguish between several connected in parallel.

How often is data sent to the server?

Sensor readings are sent to the server once a minute. Emerging events (exceeding permissible limits, etc.) - immediately upon occurrence.

Some unimportant parameters (information about balance, GSM signal level, etc.) are sent upon request from the server. The server sends requests for this data once every minute or two, but only if the user is online in the ver-interface or mobile application.

If the web interface does not sense user activity for 10 minutes, it goes into “sleep mode”. In this mode, the web interface stops updating data from the server as you move the mouse. Temperature and event data continues to be sent to the server in real time.

Explanations for setting Input 1

General comment. On the "Status" tab, the "Security" button appears for the options "motion sensor", "motion sensor with delay", "short-to-minus sensor", "minus-opening sensor". This button can be turned on or off, that is, you can make the input active or disabled.

For other options, the "Security" button is absent, that is, the input is considered to be constantly active.

  • "not used" - should be selected if it is not connected. Otherwise, you may get an alarm
  • "delayed motion sensor" - triggered when the circuit opens. There is a delay of 30 seconds. The web interface displays the message "motion detected"
  • "motion sensor without delay" - triggered when the circuit opens. The web interface displays the message "motion detected"
  • "water leakage sensor" - an analog input is used, triggered at a voltage less than 2.4V. The web interface displays the message "water leakage detected"
  • "gas leak sensor" - triggered when the circuit opens to ground. The web interface displays the message "gas leak".
  • "alarm button
  • "short circuit to negative sensor" - triggered when there is a ground fault
  • The ZONT H-1V thermostat model has a 220VAC relay, but also limited current.

Supply voltage 10-28V
Maximum current consumption 150 mA
Number of analog inputs 1
Output dry contact (make/open) 1
Type of connected wired temperature sensors DS 18S20
Type of connected radio thermal sensors ,
Total number of simultaneously connected temperature sensors 10
Maximum permissible length of cable with temperature sensors 100 m
Maximum current through relay contacts 1000 mA
Maximum voltage of switched relay contacts ~ 220 V, = 24 V
Voice interface There is
WEB interface There is
1-Wire interface There is
Operating temperature range from -30 to +55 °С
GSM modem frequency ranges 800, 900, 1800, 1900 MHz
Data link GPRS
GSM antenna external
Internal non-volatile memory There is
Built-in battery backup 103450-RSV-LD 2000 mAh
Time to reach operating mode no more than 50 sec
Average service life 7 years
dimensions 90 x 50 x 55
Weight, no more 0.200 kg
Housing material Plastic on DIN rail

WEB interface

  • display of the current state of the boiler and room temperature;
  • boiler operation control;
  • temperature monitoring (inside, outside, coolant) for any selected period of time;
  • programming boiler operation according to schedule;
  • notifications about the activation of additional sensors.
  • Remote control of boiler operation

    • management of SMS commands;
    • control when dialing to the voice menu;
    • control via the Internet (WEB interface and mobile application for Android and iOS devices).

    Event Notification

    • notification when the measured temperature deviates from the specified threshold values;
    • notification of a boiler failure (provided the thermostat is connected to the emergency output of the boiler);
    • notification of a malfunction of the temperature sensor and the thermostat going into emergency mode;
    • notification of power loss/restoration (mains) (only when the backup battery is turned on);

    Signaling

    monitoring the status of additional sensors connected to the “Alarm” input of the thermostat;

    Event memory

    • a diary of measured temperatures for any period without a statute of limitations;
    • date and time of detection of the boiler failure;
    • date and time of changing the operating mode of the boiler and thermostat;
    • executed control commands via voice menu, transmitted by SMS, software updates;
    • date and time of power failure/restoration (network).

    Remote software update

    Updating the current version of the unit's firmware without turning it off or dismantling it.

    Thermostat for controlling any electric, gas or diesel boiler.

    ZONT H-1V Intelligent thermostat for remote control of the heating boiler. When installing a ZONT thermostat, it is possible to simultaneously connect 10 temperature sensors, which allows you to control the temperature in different rooms. For example, the temperature outside, the temperature in the room, in the boiler room, the temperature of the boiler supply, return, boiler, heated floor, etc. A time graph is constructed for each temperature sensor. You can view temperature changes over a day, over a week, or over any other period of time.


    In the event of a power failure, emergency operation of the boiler, or the boiler operating parameters exceeding certain limits, an SMS notification occurs, phone call or notification on email. The operation of the boiler can be adjusted using any of the temperature sensors. You can set the comfortable, economical and anti-freeze operating modes. In addition, it is possible to program the desired temperature by time of day throughout the week. Weather-dependent control (PZA) of boiler operation according to temperature curves. In PZA mode, the thermostat controls the coolant temperature based on the outside street temperature. By connecting an additional adapter, it is possible to remotely control the boiler using the Open Therm protocol, with the transmission of possible error codes and other parameters of the boiler operation.


    The device operates via a GPRS channel using an installed SIM card. Sends data to free cloud server. It is possible to control using SMS commands or using voice control, which is undoubtedly convenient for older people who do not use smartphones and tablets. Price tariff plan Acceptance, a standard SIM card is about 120 rubles per month. For ease of use there is free apps for telephone and personal account on the website. You can connect motion sensors, water leakage sensors, gas leakage sensors to the thermostat, with arming and disarming and corresponding notification when triggered. When sensors are triggered or when a boiler alarm signal appears, the device will notify you by telephone numbers specified during setup. All settings are made independently or with the help of an installer, remotely via the Internet and your personal account. When the main power is turned off, the device sends notification information and switches to operation from the built-in battery.

    The minimum set of the device includes the thermostat itself with a power supply, one temperature sensor that will be used for control, and a SIM card

    Modern technologies have firmly entered the lives of many people and have made it much more comfortable. Indeed, now we have access to many benefits of civilization, the existence of which was quite difficult to imagine a few years ago. One of the devices that allows you to create a new level of comfort is the system Zont H-1. This system helps to remotely control the temperature in the room, monitor the health of the heating boiler, and also control it remotely!

    Convenient heating system control

    In the winter season, maintaining a comfortable climate in the house is usually ensured by a whole group of heating devices, which are not always convenient to control manually. However, with the help of the Zont H-1 smart thermostat, you can easily customize your heating system to suit your needs. This way, the house will always maintain a comfortable temperature.

    Remote control

    In addition, you have the opportunity to control the climate in your home from a distance! You can call or send the necessary command via SMS message to enable any operating mode and find out the balance SIM cards, current system state, etc. This function will be especially useful for users who may be away for a long time on business trips, travel outside the city, etc. You can remotely turn on the economical heating mode, and create a comfortable heating temperature before returning home.

    Creating a heating schedule

    Zont H-1 allows you to configure the operation of the heating system in accordance with a specific schedule. For example, if you are only at home in the evenings and on weekends, then the system will maintain a minimum temperature in your absence and provide the necessary heating upon your return. Thus, the system allows save energy resources and your funds.

    How does the system work?

    The thermostat can be controlled using voice menu, sending SMS messages or via an Internet service via PC or smartphone. To use the Internet service, you do not need to install special programs; any modern web browser(Opera, Chrome, IE 8 and above, Firefox). Access to the service is provided through the user’s personal page on the website zont-online.ru. You can also control the device using special application for Android, which is available for download at Play Market.

    Through your personal account on the zont-online.ru service.

    the user needs to set comfortable temperature values, as well as threshold levels for generating alarms when the temperature deviates to a critical value. Zont H-1 receives information about temperature changes using temperature sensor

    supplied with the system. Depending on the sensor readings, the thermostat turns off or turns on the output relay, which controls the operation of the boiler. This principle of operation allows you to maintain the required temperature in the house.

    If a malfunction occurs in the operation of the heating boiler, Zont H-1 will notify the owner, which will allow a prompt response to this event.

      System functionality

      Indoor temperature change alert:

      t˚above the set threshold

      t˚below the set threshold

      Notification when a malfunction occurs:

      if the temperature sensor is faulty

      in case of boiler failure

      Event memory:

      temperature sensor readings

      SMS commands

    • changes in operating modes

      power on/off

      software updates

      Indoor temperature monitoring:

      update period - 1 minute

      Boiler operating mode control:

      SMS commands

      via internet service

      Internet access:

      constant connection with the server

      viewing temperature graphs for any period of time

      display of thermostat status (room temperature, current operating mode, emergency operating mode indication)

      transfer of accumulated data

      changing the thermostat operating mode “in one click”

      entering and editing settings

      weekly temperature schedule editor

      Remote software update:

      The current firmware version is updated from the user's personal account upon his command.

      Supply voltage: 10-14 V

      One analog input

      One dry contact output (make/break)

      Maximum current consumption: 150 mA

      Maximum current through relay contacts: 1000 mA

      WEB interface

      1-Wire interface

      Operating temperature range: from -30 to +55 °C

      GSM modem frequency ranges: 800, 900, 1800, 1900 MHz

      GPRS data channel

      Built-in GSM antenna (optional can be external)

      Internal non-volatile memory

      Backup battery: BL-5C 1000 mA*N (optional)

      Time to reach operating mode: no more than 50 seconds.

      Overall dimensions: 77 x 86 x 33 mm

      Weight: 0.200 kg.

      Plastic case

      External GSM antenna

      Individual packing

      Mounting base

      Thermostat

      Digital temperature sensor

      Network adapter 220/12 V.

    Terminal block (2 pcs.)


    The thermostat does not come with a battery or SIM card.